Description

Series/Model: Series SLP


Low Pressure Switch

Low pressure SPST open on pressure fall

Temperatures: Ambient 20°F to 176°F (-30°C to 80°C). Fluid 60°F to 250°F(-50°C to 120°C).

Rated Voltage: 50/60 Hz, 24/120/240 Volts (6 RLA, 36 LRA)

Life at rated load: 100,000 cycles

1/4" SAE female flare fitting with valve core depressor

Snap acting stainless steel hermetically sealed sensor (SHP, SLP, and SFC)

Small size and light weight for direct mounting

Excellent set point repeatability/stability

Close PSI: 80

Open PSI: 25

Tolerance: ± 5 PSI


High precision controls at economical prices. These switches are encapsulated nonadjustable, SPST, direct mount switches for use with HFC, HCFC and CFC refrigerants. The switches are available with automatic reset in both open low and open high configurations and manual reset with open high switching. These switches can also be used as operating controls in applications such as a low ambient condenser fan control.


Details:

  • Pressure Switch
  • Type Encapsulated, Non-Adjustable, Low Pressure Open on Pressure Drop, Automatic Reset
  • Operator Type Snap-Acting Stainless Steel Hermetically Sealed Sensor
  • Operating Pressure Rating 0 to 650 PSI
  • Pressure Media Fluid
  • Contact Configuration SPST
  • Contact Rating 10 Amp at 12 to 28 Volt AC/DC, 5 Amp at 48 Volt AC/DC, 5.8 Amp at 110 to 120 Volt AC/DC, 2.9 Amp at 208 to 240 Volt AC/DC (Rated Load), 36 Amp (Locked Rotor)
  • Connection Type 1/4 Inch SAE Female Flare
  • Application Refrigerant, Air Conditioner, Heat Pump System
  • Approval UL, CE
  • Voltage Rating 24/120/240 Volt AC at 50/60 Hertz
  • Pressure Rating 25 PSI (Cut-Out), 80 PSI (Cut-In), 5000 PSI (Burst)
  • Tolerance +/-5 PSI
  • Lead Length 18 Inch
  • Wire Size 18 AWG
  • Temperature Rating -30 to 80 Deg C (Ambient), -50 to 120 Deg C (Fluid)
  • Includes Valve Core Depressor
  • Low Pressure Open on Pressure Drop SPST
  • High Pressure Open on Pressure Rise SPST
  • Manual Pressure Open on Pressure Rise SPST
  • Fan Cycle Close on Pressure Rise SPST
  • Snap Action Stainless Steel Hermetically Sealed Sensor
  • Excellent Set Point Repeatability and Stability

Safety Information


California Proposition 65 Warning SymbolWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
This product and other products on our site may contain a chemical known to the state of California to cause cancer or birth defects or other reproductive harm. Visit the state of California's website to learn more about Proposition 65.

Many of our items should be installed by a trained HVAC technician. With purchase of this item, you are agreeing to follow any and all safety guidelines provided by the manufacturer and to have the item installed by a trained HVAC technician as necessary. Your professional installer assumes all responsibility for injury or property damage that may result.

View AllClose

Warranty & Returns

The items we offer on our website are professional grade products that are designed and built to be installed by licensed, professional tradesmen. Because of the professional install these products carry a longer warranty, different than found in similar products offered by big box stores for do it yourselfers. We encourage you to be a licensed HVAC contractor or to hire a Licensed HVAC contractor to be sure you can truly get the manufacturer's warranty. Many manufacturers will request a copy of the contractor license or a bill of install to start the warranty procedure. HVAC Wholesale Direct is a distributor and is not responsible for labor claims, supplies or refrigerant cost recovery or rejected manufacturer's warranty due to misapplication or for operating outside the terms of a manufacturer's warranty.

box graphic

30-Day Hassle-Free Return Policy
After 30 days, we will still accept returns but with a 15% Restocking Fee for up to 90 Days

Return terms and conditions: Item(s) must be new and unused in the original packaging with all original documentation included.

Upon receipt of the returned item(s) an inspection will be performed to ensure the above terms and conditions have been met.
If they have, we will issue a refund back to the original method of payment used at time of sale, less our original cost of shipping. If the terms and conditions have not been met, we will contact you to arrange for the items to be returned to you at your expense.

You are responsible for return shipping costs.
We recommend you insure the shipment against loss or damage. Any return shipping damage claims will be your responsibility.


Return Instructions - Non Damage Items

You must ...

  • Request a return via our Contact Us link
  • Include your order / invoice number
  • Provide a reason for your return request
  • State if you want a replacement or a refund

Once we receive your request, we will respond with either an authorization to return, or deny the request with an explanation. If the request is authorized, we will also provide instructions on how and where to return the purchase. Upon receipt of the item(s) back, an inspection will be performed to determine if the item(s) can be returned to the shelf or not. If they can, we will comply with your request for a replacement item(s) or a refund. Refunds will always be issued back to the method of payment used for the original purchase. If the item(s) can not be returned to the shelf for resale, they will be returned to you at your expense.

Items Damaged During Shipment

Occasionally, items are damaged in shipment. It is the buyer's responsibility to inspect for damage upon receipt from the shipping / delivery company. It's best to refuse the delivery and notate the damage on the driver's bill. It's always best to take a picture and let us know, so we can make arrangements to get you a replacement as quickly as possible. Once you accept the shipment, any damage claims at that time are between the delivery company and the buyer. We inspect every item / shipment for damage prior to tendering the items to the delivery company.

Defective Items

If your reason for returning the item in the instructions above is due to a manufacturer defect, you must state that in your return request, as it will affect the instructions for returning the item. Many manufacturers have specific procedures that must be followed in order to process these claims. A detailed description of the defect must be provided. You may be asked to provide additional information such as, a service ticket showing the diagnosis from a licensed HVAC professional, pictures of the defect, etc. These additional pieces of information will help to expedite the process in many cases. Some manufacturers will not proceed without that additional information.

HVAC Wholesale Direct vendor network is made up of some of the finest manufactures of HVAC products. We will be here to assist you. We however, do not have any control over the manufacturers and their warranty practices and make no claim on honoring warranty on behalf of any manufacturer. HVAC Wholesale Direct is not responsible for shipping or freight charges for any warranty claims made that we are helping to facilitate. We issue credit after we receive credit from the manufacturer.

Electrical Parts

Electrical parts, such as capacitors, contactors, transformers, and thermostats are NON-ReturnABLE. HVAC Wholesale Direct is not liable for improper selection and/or installation of electrical parts and controls.

At the end of the day we are people doing business with people in a modern environment. We want you to be happy with your experience with our company. We promise to work with all of our customers, within good reason, to resolve any conflicts, whether defective or mis-ordered to your satisfaction.

View AllClose

Specifications

Type:
Encapsulated, Non-Adjustable, Low Pressure Open on Pressure Drop, Automatic Reset
Operator Type:
Snap-Acting Stainless Steel Hermetically Sealed Sensor
Operating Pressure Rating:
0 to 650 PSI
Pressure Media:
Fluid
Contact Configuration:
SPST
Contact Rating:
10 Amp at 12 to 28 Volt AC/DC, 5 Amp at 48 Volt AC/DC, 5.8 Amp at 110 to 120 Volt AC/DC, 2.9 Amp at 208 to 240 Volt AC/DC (Rated Load), 36 Amp (Locked Rotor)
Connection Type:
1/4 Inch SAE Female Flare
Application:
Refrigerant, Air Conditioner, Heat Pump System
Approval:
UL, CE