Diversitech

WET Switch FLOOD Detector WS-1

(No reviews yet) Write a Review
SKU:
16901
UPC:
095247149995
MPN:
WS-1
Condition:
New
Package Weight:
0.66 LBS
Shipping:
Calculated at Checkout
$65.39

Description

Wet Switch Flood Detector

Designed to detect the presence of condensate runoff water

Connects to 24V power system

LEDs show power and system status

Multiple units may be connected

Now with isolated contacts

Wire connectors and system labels included


A solid state control designed to help prevent flooding, damage to carpets, walls, furniture, ceilings, etc. Now has a built-in test and reset button for easier installation. Turns system off when detecting moisture due to condensate or drain leaks. One or two drops will cause Wet Switch to turn off a unit, alerting a serviceman to a moisture problem. A lit LED indicates the Wet Switch is activated and has turned the unit off. Reset simply by drying the absorbent pad with a paper towel and pressing the reset switch. Connects to 24 VAC. More than one unit may be connected to a system. 2 amp contact rating. Simple 5 wire installation. Sales displays available. ETL Listed File Number 3146992.


Details:

  • Condensate Drain Switch Flood Detector
  • Item Flood Detector
  • Display Type LED
  • Used On Item Condensate Drain Switch
  • Applicable Standard UL 508, ETL
  • Voltage Rating 24 Volt AC
  • Contact Rating 2 Amp
  • Integral Feet-Integral feet raise the hydrophilic pad and sensor array off the drain pan slightly to prevent nuisance tripping and pan corrosion (metal pans only) from interfering with the sensor array
  • Hydrophilic Pad-A high tech polymeric fiber quickly draws water into the sensor array using proven capillary technology
  • Multiple Unit Connectivity-Multiple unit connectivity allows for multiple Wet Switches to be connected in series to adequately cover large drain pan areas
  • Standard 24AC Control-Power supply to the Wet Switch® is 24VAC, the standard power available on most air handler units. This makes hookup quick and easy. There is no need to run different power to the switch
  • Double Throw Relay-The double throw relay allows for wiring to interrupt the system and to sound an alarm (by others) when moisture is detected
  • Stainless Steel Sensor Array-A high tech array of multiple stainless steel sensors detects even a minimal amount of water drawn into the hydrophilic pad
  • Solid State Electronics-Proven electronics prevent mechanical failure in an aggressive operating environment
  • Push to Reset-When the Wet Switch® activates, it locks out the call for cool circuit on the air conditioner until the switch is manually reset. This prevents continuing damage in cases where the overflow water drains out of the pan, onto the surrounding ceiling
  • Push to Test-The push to test button on Wet Switch® gives the installer a quick, easy way to test the wiring on their installation

Safety Information


California Proposition 65 Warning SymbolWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
This product and other products on our site may contain a chemical known to the state of California to cause cancer or birth defects or other reproductive harm. Visit the state of California's website to learn more about Proposition 65.

Many of our items should be installed by a trained HVAC technician. With purchase of this item, you are agreeing to follow any and all safety guidelines provided by the manufacturer and to have the item installed by a trained HVAC technician as necessary. Your professional installer assumes all responsibility for injury or property damage that may result.

View AllClose

Warranty & Returns

The items we offer on our website are professional grade products that are designed and built to be installed by licensed, professional tradesmen. Because of the professional install these products carry a longer warranty, different than found in similar products offered by big box stores for do it yourselfers. We encourage you to be a licensed HVAC contractor or to hire a Licensed HVAC contractor to be sure you can truly get the manufacturer's warranty. Many manufacturers will request a copy of the contractor license or a bill of install to start the warranty procedure. HVAC Wholesale Direct is a distributor and is not responsible for labor claims, supplies or refrigerant cost recovery or rejected manufacturer's warranty due to misapplication or for operating outside the terms of a manufacturer's warranty.

box graphic

30-Day Hassle-Free Return Policy
After 30 days, we will still accept returns but with a 15% Restocking Fee for up to 90 Days

Return terms and conditions: Item(s) must be new and unused in the original packaging with all original documentation included.

Upon receipt of the returned item(s) an inspection will be performed to ensure the above terms and conditions have been met.
If they have, we will issue a refund back to the original method of payment used at time of sale, less our original cost of shipping. If the terms and conditions have not been met, we will contact you to arrange for the items to be returned to you at your expense.

You are responsible for return shipping costs.
We recommend you insure the shipment against loss or damage. Any return shipping damage claims will be your responsibility.


Return Instructions - Non Damage Items

You must ...

  • Request a return via our Contact Us link
  • Include your order / invoice number
  • Provide a reason for your return request
  • State if you want a replacement or a refund

Once we receive your request, we will respond with either an authorization to return, or deny the request with an explanation. If the request is authorized, we will also provide instructions on how and where to return the purchase. Upon receipt of the item(s) back, an inspection will be performed to determine if the item(s) can be returned to the shelf or not. If they can, we will comply with your request for a replacement item(s) or a refund. Refunds will always be issued back to the method of payment used for the original purchase. If the item(s) can not be returned to the shelf for resale, they will be returned to you at your expense.

Items Damaged During Shipment

Occasionally, items are damaged in shipment. It is the buyer's responsibility to inspect for damage upon receipt from the shipping / delivery company. It's best to refuse the delivery and notate the damage on the driver's bill. It's always best to take a picture and let us know, so we can make arrangements to get you a replacement as quickly as possible. Once you accept the shipment, any damage claims at that time are between the delivery company and the buyer. We inspect every item / shipment for damage prior to tendering the items to the delivery company.

Defective Items

If your reason for returning the item in the instructions above is due to a manufacturer defect, you must state that in your return request, as it will affect the instructions for returning the item. Many manufacturers have specific procedures that must be followed in order to process these claims. A detailed description of the defect must be provided. You may be asked to provide additional information such as, a service ticket showing the diagnosis from a licensed HVAC professional, pictures of the defect, etc. These additional pieces of information will help to expedite the process in many cases. Some manufacturers will not proceed without that additional information.

HVAC Wholesale Direct vendor network is made up of some of the finest manufactures of HVAC products. We will be here to assist you. We however, do not have any control over the manufacturers and their warranty practices and make no claim on honoring warranty on behalf of any manufacturer. HVAC Wholesale Direct is not responsible for shipping or freight charges for any warranty claims made that we are helping to facilitate. We issue credit after we receive credit from the manufacturer.

Electrical Parts

Electrical parts, such as capacitors, contactors, transformers, and thermostats are NON-ReturnABLE. HVAC Wholesale Direct is not liable for improper selection and/or installation of electrical parts and controls.

At the end of the day we are people doing business with people in a modern environment. We want you to be happy with your experience with our company. We promise to work with all of our customers, within good reason, to resolve any conflicts, whether defective or mis-ordered to your satisfaction.

View AllClose

Specifications

Item:
Flood Detector
Display Type:
LED
Used On Item:
Condensate Drain Switch
Applicable Standard:
UL 508, ETL
UOM:
ea
View AllClose

0 Reviews

View AllClose